Part 4 (1/2)
TEST NO 1[I]
Marks on coluht 1-1/8-in round bars vertically
Band spacing--- 9 in vertically
Hooped with seven 32-in wire spirals about 2-in raise
Outside diameter of hoops--14-1/2 in
Total load at failure--1,360,000 lb
Remarks--Point of failure was about 22 in from the top Little indication of failure until ulti off of concrete near the top cap, due possibly to the cap not being well seated in the column itself
TEST NO 2
Marks on coluht 1-1/8-in round bars vertically
Band spacing about 13 in vertically
Wire spiral about 3-in pitch
Point of failure about 18 in from top
Top of cast-iron cap cracked at four corners
Ultimate load--1,260,000 lb
Remarks--Both caps apparently well seated, as was the case with all the subsequent tests
TEST NO 3
Marks on coluht 7/8-in round bars vertically
Hoops--1-3/4 in 3/16 in 14 in outside dia--13 in vertically
Ultimate load--900,000 lb
Point of failure about 2 ft from top